Sökningen fann 26 träffar

av Nemo
mån 25 jan, 2016 13:28
Kategori: Värmebaronen
Tråd: Time delayed start
Svar: 16
Visningar: 3311

Re: Time delayed start

Hejsan I´m ready to make a midway status. Still at a maximum of 5-6 starts from 40-45 celsius to 75 celsius and slightly increased pump-flow. I have saved pellets and am pretty sure that I will use between 2700-3000kg for this season. Last season I spend 3050kg and it was a slightly milder winter. T...
av Nemo
fre 11 dec, 2015 10:11
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Kopplingshjälp sökes till acktank på liten yta
Svar: 8
Visningar: 3810

Re: Kopplingshjälp sökes till acktank på liten yta

I cant quite discern whether you´ve actually already bought and ack-tank. If not why not take a look at värmebaronens 750l teknik tank it its 76cm wide but I can´t remember how deep it is. I have a 300l ack tank with two external pladevarmevekslere - it is made to be very compact - but of course a l...
av Nemo
tor 03 dec, 2015 17:19
Kategori: PELLETS - Eldning, Brännare, Pannor, Allmänt
Tråd: Kombinationer panna/brännare
Svar: 219
Visningar: 332891

Re: Kombinationer panna/brännare

Panna: Pellmax Ub - installerad 2013

Brännare: Viking Bio 20 - 2013

Acktank: 300 Liter

Skorsten: Isokern 6m

Small Pelletshopper - 120kg (Värmebaronens compact løsning)

Solvarme: 60 rör

Plus: stabil och lavt forbrug

Minus: small pellets storage
av Nemo
ons 02 dec, 2015 14:19
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Sparer man pellets med Ack-Tank?
Svar: 12
Visningar: 10626

Re: Sparer man pellets med Ack-Tank?

well there are some variations according to season and where in Denmark You live. People closer to Germany often drive to get pellets from there, or even hire a larger truckload. where I live, Northern Jutland, the price pr kg is roughly 1.7 to 2.4 kroner. Depending on season, and if you pick them u...
av Nemo
ons 02 dec, 2015 13:09
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Sparer man pellets med Ack-Tank?
Svar: 12
Visningar: 10626

Re: Sparer man pellets med Ack-Tank?

You make som very good points. I never thought about the issue with 'hard water' but it makes sense that one adapts the technology to the surroundings. Also I would like to clarify, just because NBE´s products isn´t something for me, they are still very good and very conservatively priced products (...
av Nemo
ons 02 dec, 2015 09:58
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Sparer man pellets med Ack-Tank?
Svar: 12
Visningar: 10626

Re: Sparer man pellets med Ack-Tank?

Honda I love your answer - thank you so much! :D I been on a Danish forum but left it because I almost exclusively got grief and harsh words from my choice of heating system. I saw the strength of the more straight forward on/off system early on, and when I opted for solar heating there was just no ...
av Nemo
ons 02 dec, 2015 06:47
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Sparer man pellets med Ack-Tank?
Svar: 12
Visningar: 10626

Re: Sparer man pellets med Ack-Tank?

I see the reduction in electricity use already (which actually allows me to keep the boiler shut down completely from mid April to mid October due to the extra electricity my solar cells generates. There is an 6kw El-patron/charger in the ack-tank and I have heatpipes for solarheating). I can write ...
av Nemo
tis 01 dec, 2015 18:48
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Sparer man pellets med Ack-Tank?
Svar: 12
Visningar: 10626

Re: Sparer man pellets med Ack-Tank?

sure - your english is fine :D - and you are welcome to reply in swedish as I read the language reasonably well. My starts have been halved by the use of a buffertank, which allows me to delay my starts by 135 mins, and the burning time have increased from 25-40 mins to 60+ minutes. Roughly this add...
av Nemo
mån 30 nov, 2015 19:57
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Sparer man pellets med Ack-Tank?
Svar: 12
Visningar: 10626

Re: Sparer man pellets med Ack-Tank?

So basically only ack-tank if You have solar heating, brænder ved etc. But what if the ack-tank stands in a place where the spild-värme is used, and not just lost? We do agree that a burner start costs xtra pellets and thats why it is good to have few starts (and long heating/burning times for high ...
av Nemo
mån 30 nov, 2015 17:25
Kategori: ACKUMULATORTANK / KOPPLINGAR
Tråd: Sparer man pellets med Ack-Tank?
Svar: 12
Visningar: 10626

Sparer man pellets med Ack-Tank?

Hello (feel free to answer in Swedish) I´ve been thinking about this for a while and it seems that there is no clear answer. I know people with on/off pelletburners with and without ack-tank and the only thing there seems to be a given is that the number of starts are reduced relatively to the size ...
av Nemo
sön 29 nov, 2015 14:27
Kategori: Värmebaronen
Tråd: Time delayed start
Svar: 16
Visningar: 3311

Re: Time delayed start

Just writing to share some of my experiences. I´m still at maximum time delay despite some serious storms (our house really takes the brunt as it is adjacent to open fields). I have however increased the flow from 6 watts to 11-14 watts from the pump to the house. Max temp. is still 75-76 degrees. I...
av Nemo
tis 27 okt, 2015 16:34
Kategori: Värmebaronen
Tråd: Time delayed start
Svar: 16
Visningar: 3311

Re: Time delayed start

ah I see, that seems do-able for me. Thank You for sharing. El-priserne i DK er pt cirka 2 dkr pr. k Wh . However as I have solar panels/cells and solar heating it doesn´t really concern me - the boiler is completely shut down from 15/4 to 15/10. The delayed start is still helpfull though esp. here ...
av Nemo
mån 26 okt, 2015 21:36
Kategori: Värmebaronen
Tråd: Time delayed start
Svar: 16
Visningar: 3311

Re: Time delayed start

what kind of tidur is that - how does that work? I´m curious :D
av Nemo
mån 26 okt, 2015 17:42
Kategori: Värmebaronen
Tråd: Time delayed start
Svar: 16
Visningar: 3311

Re: Time delayed start

If I raise the temp to 70 it will top off at 85 cirka - that´s too high for comfort. I think I´ll keep the settings as they are now, for as long as possible - I suspect it will become too cold for the current settings when it gets colder. I will return when I have more experience or when the boiler ...
av Nemo
mån 26 okt, 2015 10:49
Kategori: Värmebaronen
Tråd: Time delayed start
Svar: 16
Visningar: 3311

Re: Time delayed start

Hello again Just wrote to the dealer - he says that two major reasons allow for the pellmax ub boiler to reach lower temperatures before ignition. 1) The large amount of water relative to the boilers modest size (I would have thought it was the other way around but apparently not) 2) The core of the...